{"id":3314,"date":"2026-06-10T19:33:50","date_gmt":"2026-06-10T19:33:50","guid":{"rendered":"https:\/\/mywarmhome.co.uk\/stage\/?page_id=3314"},"modified":"2026-10-11T14:48:44","modified_gmt":"2026-10-11T14:48:44","slug":"intermittent-ventilation","status":"publish","type":"page","link":"https:\/\/mywarmhome.co.uk\/stage\/intermittent-ventilation\/","title":{"rendered":"Intermittent Ventilation"},"content":{"rendered":"\n<div class=\"wp-block-group alignfull mwh2-page is-layout-flow wp-block-group-is-layout-flow\">\n<div class=\"wp-block-cover alignfull has-parallax has-custom-content-position is-position-center-left mwh2-heating-hero\" style=\"padding-top:0;padding-bottom:0;min-height:520px;aspect-ratio:unset;\"><div role=\"img\" aria-label=\"Ventilation in the home\" class=\"wp-block-cover__image-background wp-image-3908 size-full has-parallax\" style=\"background-position:50% 50%;background-image:url(https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/09\/vent1.png)\"><\/div><span aria-hidden=\"true\" class=\"wp-block-cover__background has-custom-color-1-background-color has-background-dim-30 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div class=\"wp-block-group alignwide has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-label mwh2-label-light wp-block-paragraph\">VENTILATION \/ MY WARM HOME<\/p>\n\n\n\n<h1 class=\"wp-block-heading mwh2-display has-accent-5-color has-text-color has-link-color wp-elements-1\">Intermittent extract ventilation.<\/h1>\n\n\n\n<p class=\"mwh2-lead has-accent-5-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\">Removing moisture and pollutants at source \u2014 with the right fan, airflow, controls and replacement-air path.<\/p>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-ribbon has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns alignwide mwh2-ribbon-grid is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"mwh2-ribbon-no wp-block-paragraph\">01<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Understand<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Local extraction and how controls operate.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"mwh2-ribbon-no wp-block-paragraph\">02<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Follow the air<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Moisture out and replacement air in.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"mwh2-ribbon-no wp-block-paragraph\">03<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Weigh it up<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Benefits, limitations and system comparisons.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"mwh2-ribbon-no wp-block-paragraph\">04<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Design &amp; check<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Installed airflow, commissioning and maintenance.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-section mwh2-intro has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:38%\">\n<p class=\"mwh2-label wp-block-paragraph\">THE SHORT VERSION<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-section-heading\">A fan is only one part of the system.<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:62%\">\n<p class=\"mwh2-lead wp-block-paragraph\">Intermittent extract ventilation (IEV) removes moisture and pollutants from kitchens, bathrooms and other wet rooms \u2014 but only while the fan is running.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Extract rate, duct route, controls, external terminal and replacement-air path must work together.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A bathroom or kitchen extractor switched on after showering or during cooking is an example of IEV. As insulation, new windows and draught-proofing reduce unintended air leakage, the planned ventilation strategy becomes more important.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-section mwh2-handbook has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<p class=\"mwh2-label wp-block-paragraph\">01 \/ THE BASICS<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-section-heading mwh2-handbook-heading\">What is intermittent extract ventilation?<\/h2>\n\n\n\n<p class=\"mwh2-lead wp-block-paragraph\">IEV uses local extractor fans when moisture, odours or pollutants are produced. They are normally installed in wet rooms such as bathrooms, kitchens, utility rooms, en-suites and WCs.<\/p>\n\n\n\n<div class=\"wp-block-columns alignwide mwh2-topic-grid is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-orange has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">01<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Manual switching<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A light switch, separate switch or pull cord starts the fan.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-blue has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">02<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Overrun timer<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A timer may keep extraction running after the switch is turned off.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-green has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">03<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Humidity sensor<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A suitable automatic control can respond to increased indoor humidity.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-red has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">04<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Outdoor discharge<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Extract air must discharge outdoors \u2014 never into a loft, roof void or other internal space.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Control selection depends on the room, its use and the applicable building guidance.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-feature-band has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:42%\">\n<p class=\"mwh2-label mwh2-label-light wp-block-paragraph\">02 \/ FOLLOW THE AIR<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-feature-heading\">How intermittent extraction works.<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58%\">\n<p class=\"mwh2-lead has-base-color has-text-color has-link-color wp-elements-3 wp-block-paragraph\">Every part of the air path matters. Closed background vents, obstructed internal transfer routes and restrictive ductwork can all reduce actual performance.<\/p>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">01 \/ Moisture is produced<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Showering, cooking and drying clothes release water vapour and pollutants.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">02 \/ The fan extracts<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Air is drawn from the wet room through a wall or duct route.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">03 \/ Air leaves outdoors<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Moist air, odours and pollutants discharge at the external terminal.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">04 \/ Replacement air enters<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Background ventilators and suitable internal transfer paths help replace the extracted air.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">05 \/ The fan stops<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A switch, timer or sensor ends the extract period until it is needed again.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-section mwh2-handbook has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<p class=\"mwh2-label wp-block-paragraph\">03 \/ WHERE IT HELPS<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-section-heading mwh2-handbook-heading\">The benefits of intermittent extract.<\/h2>\n\n\n\n<div class=\"wp-block-columns alignwide mwh2-topic-grid is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-orange has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">01<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Simple to retrofit<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A suitable local fan may be easier to add during a kitchen, bathroom or utility-room refurbishment than a whole-house ducted system.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-blue has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">02<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Source control<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Extracting where moisture and pollutants are generated helps reduce their spread through the home.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-green has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">03<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Low fan energy<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Modern efficient fans generally use little electricity during their operating periods.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extractwindow.jpg\" alt=\"Window-mounted intermittent extractor fan\" class=\"wp-image-3320\" srcset=\"https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extractwindow.jpg 800w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extractwindow-300x300.jpg 300w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extractwindow-150x150.jpg 150w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extractwindow-768x768.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Window-mounted extract fan.<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extract1.jpg\" alt=\"Older style intermittent extractor fan\" class=\"wp-image-3319\" srcset=\"https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extract1.jpg 800w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extract1-300x300.jpg 300w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extract1-150x150.jpg 150w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extract1-768x768.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Older fan designs may be noisy or inefficient.<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extract-wind.jpg\" alt=\"External extractor terminal near a building opening\" class=\"wp-image-3318\" srcset=\"https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extract-wind.jpg 800w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extract-wind-300x300.jpg 300w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extract-wind-150x150.jpg 150w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/extract-wind-768x768.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">Terminal position needs careful consideration.<\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Ventilation helps manage moisture; it does not cure every damp problem.<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Leaks, rising or penetrating damp, missing insulation, thermal bridges and inadequate heating need their own diagnosis. Mould should not automatically be blamed on occupant behaviour.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-feature-band has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:42%\">\n<p class=\"mwh2-label mwh2-label-light wp-block-paragraph\">03 \/ KNOW THE LIMITS<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-feature-heading\">The limitations of intermittent extract.<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58%\">\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Works only while running<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">If the fan is not switched on, stops too early or is isolated because of noise, moisture can remain.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Installed airflow can fall<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Long, crushed or restrictive ductwork and unsuitable external terminals can reduce delivered airflow.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Not automatically whole-house ventilation<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Local wet-room extraction needs suitable background ventilation and internal air-transfer paths.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Depends on how it is used<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Manual systems rely on occupants running the fans when needed and for long enough.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Noise and comfort matter<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">A noisy fan may be avoided even if its performance looks satisfactory on paper.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-section mwh2-intro has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:38%\">\n<p class=\"mwh2-label wp-block-paragraph\">03 \/ CHOOSE THE STRATEGY<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-section-heading\">Intermittent or continuous ventilation?<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:62%\">\n<p class=\"mwh2-lead wp-block-paragraph\">Intermittent extract runs on demand or through automatic controls. Continuous MEV and MVHR generally operate at a low background rate, with boost when needed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Installation and moisture control<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEV normally uses simpler local fans and shorter ducts, and is effective at source when used properly. Continuous systems provide ventilation more consistently over occupied periods, but require their own careful design and commissioning.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Supply air and heat recovery<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">IEV and MEV rely on designed background and transfer-air paths. MVHR mechanically supplies filtered air. IEV and MEV have no heat recovery; properly designed and balanced MVHR can recover heat.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The appropriate solution depends on the property, occupancy, airtightness, layout and retrofit plans \u2014 not one feature alone.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-section mwh2-handbook has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<p class=\"mwh2-label wp-block-paragraph\">04 \/ MAKE IT WORK IN PRACTICE<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-section-heading mwh2-handbook-heading\">Seven checks for a better installation.<\/h2>\n\n\n\n<div class=\"wp-block-columns alignwide mwh2-topic-grid is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-orange has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">01<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Assess the whole home<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Review existing extract, background ventilators, door undercuts, occupancy, moisture sources and planned airtightness work.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-blue has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">02<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Select the required duty<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The fan must achieve required airflow against the resistance of the installed duct and terminal, not just in free air.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-green has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">03<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Keep ductwork effective<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Use the shortest practical route, limit bends, support ducts and avoid crushed flexible ducting.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-red has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">04<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Provide replacement air<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Keep designed background ventilators and internal transfer paths available.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide mwh2-topic-grid is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-orange has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">05<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Use suitable controls<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Timers, humidity sensors or other automatic controls can reduce reliance on memory when set correctly.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-blue has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">06<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Commission and demonstrate<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Measure airflow where required, explain the controls and give the homeowner relevant information.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-group mwh2-topic mwh2-topic-green has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"mwh2-topic-no wp-block-paragraph\">07<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Maintain performance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Clean grilles and terminals, remove grease and dust, and investigate changes in noise or extract performance.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-feature-band has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:42%\">\n<p class=\"mwh2-label mwh2-label-light wp-block-paragraph\">BUILDING REGULATIONS &amp; GUIDANCE<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-feature-heading\">Check the rules that apply to your project.<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:58%\">\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Different UK nations<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ventilation requirements vary by nation and can depend on when the work was notified or started.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">England: Approved Document F<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">This gives guidance for dwellings, including work to existing homes.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Official guidance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.gov.uk\/government\/publications\/ventilation-approved-document-f\">Read current Approved Document F \u2192<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group mwh2-service-line has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Explore related guidance<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/mywarmhome.co.uk\/stage\/regulations\/\">MyWarmHome regulations guide \u2192<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-section mwh2-handbook has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<p class=\"mwh2-label wp-block-paragraph\">REGULATIONS ILLUSTRATED<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-section-heading mwh2-handbook-heading\">Always check the guidance applicable to the project.<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/buildingregs-1024x683.jpg\" alt=\"Illustration representing UK building regulations and ventilation guidance\" class=\"wp-image-3336\" srcset=\"https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/buildingregs-1024x683.jpg 1024w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/buildingregs-300x200.jpg 300w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/buildingregs-768x512.jpg 768w, https:\/\/mywarmhome.co.uk\/stage\/wp-content\/uploads\/2026\/06\/buildingregs.jpg 1536w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Illustration only \u2014 always check the relevant current guidance.<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-section mwh2-intro has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:38%\">\n<p class=\"mwh2-label wp-block-paragraph\">IS IEV RIGHT FOR YOUR HOME?<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-section-heading\">Ventilation belongs in the retrofit plan.<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:62%\">\n<p class=\"mwh2-lead wp-block-paragraph\">IEV may suit many existing homes where assessment confirms that local extraction, background ventilation and transfer paths can work together. It can be practical during kitchen, bathroom and utility-room refurbishment.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Following significant airtightness improvements, do not assume the previous ventilation arrangement remains adequate. Review the whole-house strategy before or alongside energy-efficiency work.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Intermittent extraction must be properly selected, installed, commissioned and used, with ventilation considered alongside insulation and heating.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-section mwh2-proof has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<div class=\"wp-block-columns alignwide are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33%\">\n<p class=\"mwh2-big-stat wp-block-paragraph\">1<\/p>\n\n\n\n<p class=\"mwh2-stat-label wp-block-paragraph\">whole home \u2014 heat, moisture and fresh air working together.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:67%\">\n<p class=\"mwh2-label wp-block-paragraph\">MY WARM HOME VIEW<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-section-heading\">A fan should be part of the ventilation plan.<\/h2>\n\n\n\n<p class=\"mwh2-lead wp-block-paragraph\">A warm, energy-efficient home also needs to be dry, healthy and well ventilated.<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull mwh2-cta has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\" style=\"padding-top:23px;padding-bottom:23px\">\n<div class=\"wp-block-columns alignwide are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-794e3cfa wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:68%\">\n<p class=\"mwh2-label wp-block-paragraph\">BEFORE YOU INSULATE OR SEAL THE HOME<\/p>\n\n\n\n<h2 class=\"wp-block-heading mwh2-cta-title\">Plan ventilation before problems begin.<\/h2>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:32%\">\n<p class=\"mwh2-copy wp-block-paragraph\">Consider the building, occupants, extract fans and replacement-air routes together.<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>01 Understand Local extraction and how controls operate. 02 Follow the air Moisture out and replacement air in. 03 Weigh it up Benefits, limitations and system comparisons. 04 Design &amp; check Installed airflow, commissioning and maintenance. THE SHORT VERSION A fan is only one part of the system. Intermittent extract ventilation (IEV) removes moisture and [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"pagelayer_contact_templates":[],"_pagelayer_content":"","footnotes":""},"class_list":["post-3314","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/mywarmhome.co.uk\/stage\/wp-json\/wp\/v2\/pages\/3314","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/mywarmhome.co.uk\/stage\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mywarmhome.co.uk\/stage\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mywarmhome.co.uk\/stage\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mywarmhome.co.uk\/stage\/wp-json\/wp\/v2\/comments?post=3314"}],"version-history":[{"count":22,"href":"https:\/\/mywarmhome.co.uk\/stage\/wp-json\/wp\/v2\/pages\/3314\/revisions"}],"predecessor-version":[{"id":4868,"href":"https:\/\/mywarmhome.co.uk\/stage\/wp-json\/wp\/v2\/pages\/3314\/revisions\/4868"}],"wp:attachment":[{"href":"https:\/\/mywarmhome.co.uk\/stage\/wp-json\/wp\/v2\/media?parent=3314"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}